首页> 外文会议>TMS Annual Meeting Exhibition;Symposium on Magnesium Technology >Quantitative Analysis of Impurity Elements in Pure Magnesium by Glow Discharge Mass Spectrometry (GDMS)
【24h】

Quantitative Analysis of Impurity Elements in Pure Magnesium by Glow Discharge Mass Spectrometry (GDMS)

机译:辉光放电质谱法定量分析纯镁中的杂质元素

获取原文

摘要

In this paper, the method of quantitative analysis by GDMS of Fe, Si, Cu, and other nine impure elements in pure magnesium was studied. The applicable method for the preparation of samples was confirmed. The isotopes, resolution, and the analysis conditions were optimized. In addition, RSF of these impure elements was obtained using standard samples in order to correct the standard RSF. The results showed that using wire cutting introduces fewer impurities. When the discharge current was 55 mA and the gas flow was 350 mL/min, matrix signal was stable and suitable. Quantitative analysis of samples with the RSF_(314) showed better precision and accuracy than using the standard RSF. Comparison with the results of ICP-AES, AAS, and ICP-MS, the testing results were closer to the standard value which were obtained by our studies. But our method was more convenient on sample preparation, faster analysis speed, and higher overall accuracy than other means.
机译:本文研究了纯镁中铁、硅、铜等九种杂质元素的GDMS定量分析方法。确定了样品制备的适用方法。对同位素、分辨率和分析条件进行了优化。此外,使用标准样品获得这些不纯元素的RSF,以校正标准RSF。结果表明,使用线切割引入的杂质较少。当放电电流为55ma,气体流量为350ml/min时,基体信号稳定合适。用RSF(314)对样品进行定量分析,显示出比使用标准RSF更好的精密度和准确度。与ICP-AES、AAS和ICP-MS的结果相比,测试结果更接近我们研究得出的标准值。但与其他方法相比,我们的方法制备样品更方便,分析速度更快,整体准确度更高。