Study on Operating and Control Strategies for Hybrid Ground Source Heat Pump System

机译:混合地源热泵系统的运行与控制策略研究

获取原文

摘要

The application of hybrid ground source heat pump (HGSHP) system with cooling tower as supplemental heat rejecter is popular in the cooling-dominated area, which can mitigate the heat accumulation effect in the soil and improve the system performance. In this paper, three common operating and control strategies of the HGSHP system were analysed for optimizing selection. Simulation models of the compound ground source heat pump system were established in order to quantify the effects of different control strategies on the system performance. A comparative study was presented to investigate the advantages and drawbacks of various operating strategies in a HGSHP system using cooling tower as supplemental heat rejection based on this simulation model. An actual small office building in Shanghai was employed as the research object. The conclusion is drawn that taking the fluid temperature in the inlet of the ground-loop heat exchanger as the main control parameter while the difference between the outlet fluid temperature of heat pump and the local wet-bulb temperature as the subordinate control parameter is the best way to optimize the performance of HGSHP system.
机译:混合地源热泵(HGSHP)和冷却塔作为补充热回收器的应用在冷却主导区域中流行,可以减轻土壤中的蓄热效果,提高系统性能。在本文中,分析了HGSHP系统的三种常见操作和控制策略以优化选择。建立了复合地源热泵系统的仿真模型,以量化不同控制策略对系统性能的影响。提出了一种比较研究,研究了使用冷却塔作为基于该模拟模型作为补充散热的HGSHP系统中各种操作策略的优缺点。上海实际的小型办公楼被聘为研究对象。绘制的结论是,在地环热交换器的入口处作为主控制参数,热泵出口流体温度与本地湿灯泡温度之间的差异是最好的优化HGSHP系统性能的方法。