首页> 外文会议>International Wroclaw Symposium on Electromagnetic Compatibility;EMC 2010;EUROPE 2010;International Symposium on Electromagnetic Compatibility >Ergonomically realistic assessment of hazards related to electromagnetic fields exposure while the use of welding devices
【24h】

Ergonomically realistic assessment of hazards related to electromagnetic fields exposure while the use of welding devices

机译:在使用焊接装置时对电磁场曝光有关的符合人体工程学的逼真评价

获取原文

摘要

The paper presents realistic and standardized approach to modeling the electromagnetic hazards from gun resistant welding devices. Numerical calculations of induced current densities and internal electric field were carried out with the use of 5. and 95. centile workers body models. Investigations concerned both realistic workers posture and postures of geometries A, B and C stated in EN 50505:2007. The results shown that standardized geometries of exposure scenarios recommended by EN 50505:2007 standard may not cover the worst case of worker's exposure to magnetic field from gun welding device (representing by induced current density and internal E-field).
机译:本文介绍了抗枪抗焊装置的电磁危害建模的现实和标准化方法。 使用5.和95的使用,进行了诱导电流密度和内部电场的数值计算。梅利工人机身模型。 调查涉及现实工人的姿势和几何形状A,B和C在EN 50505:2007中所述。 结果表明,EN 50505:2007标准推荐的曝光方案的标准化几何形状可能不会涵盖从枪焊接装置(代表诱导电流密度和内部E场)的工作人员暴露于磁场的最坏情况。