首页> 外文会议>International Conference on Electric Technology and Civil Engineering >Effect of operation conditions on fouling of immersed ultrafiltration membrane for drinking water treatment of surface water
【24h】

Effect of operation conditions on fouling of immersed ultrafiltration membrane for drinking water treatment of surface water

机译:运作条件对浸渍超滤膜结垢的影响,用于饮用水处理水处理水处理

获取原文

摘要

Effect of operating conditions on the fouling of immersed ultrafiltration(UF) membrane for the Suzhou Internal River was investigated with a pilot scale study. Results show that fouling could be reduced by both the continuous aeration and intermittent aeration, while the aeration intensity should be selected reasonably. Fouling could be reduced by intermittent filtration only due to the decrease of the filtration duration, but the combination of aeration and intermittent filtration could have better control of fouling. The transmembrane pressure (TMP) of UF operation could be significantly reduced by coagulation pretreatment and the combination of coagulation, aeration and backwashing could have better mitigation of membrane fouling in the real application of immersed UF.
机译:试点规模研究研究了苏州内河浸渍超滤(UF)膜污垢的效果。 结果表明,连续通气和间歇通气可以减少污垢,而应合理地选择曝气强度。 由于过滤持续时间的降低,间歇过滤可以减少污垢,但通气和间歇过滤的组合可以更好地控制污垢。 UF操作的跨膜压力(TMP)通过凝血预处理可以显着降低,并且凝血,曝气和反洗的组合可以更好地减轻嵌入UF的真实应用中的膜污染。