Voltage sags has been identified as the largest negative impact on industrial productivity due to a sensitivity of electrical loads, and several voltage sag immunity standards such as SEMI F47, CEBMA Curve and IEC 61000-4-11, −34 were founded to improve equipment reliability, uptime and to reduce service costs. In this paper, a novel voltage sags controller along with a new RMS averaging method, which achieves not only a fast response but also a simple implementation, is proposed for the voltage sag protector employing a single-phase ac-ac voltage converter with an autotransformer. Simple and easy implementation of the converter due to no requirement of energy storage device and synchronization of voltage phase makes hardware cost-effective. A slow detection of a conventional RMS averaging method, which have been identified as a major problem, is improved by new scheme, where all stored voltage data within a queue is tuned up by new coming voltage data, is adopted for the new RMS averaging method. Experimental results are presented to verify the fast dynamics of the proposed voltage sag controller
机译:由于电负载的灵敏度,电压凹陷已被识别为对工业生产率的最大负面影响,以及多个电压下滑免疫标准,如半F47,CEBMA曲线和IEC 61000-4-11,− 34成立提高设备可靠性,正常运行时间,降低服务成本。本文采用新颖的电压SAG控制器以及一种新的RMS平均方法,该方法不仅实现了快速响应而且实现了简单的实现,而是针对采用自耦变压器的单相AC-AC电压转换器的电压SAG保护器提出了简单的实现。 。由于无需能量存储装置和电压阶段的同步而简单且容易实现转换器使硬件具有成本效益。通过新方案改善了已经被识别为主要问题的传统RMS平均方法的慢检测,其中新的RMS平均方法采用了新的即将到来的队列中的所有存储电压数据。 。提出了实验结果以验证所提出的电压凹槽控制器的快速动态

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号