首页> 外文会议>IFAC/CIGRE sysposium on control of power systems and power plants >FAULT SECTION ESTIMATION IN POWER SYSTEMS BASED ON A PROTECTION SYSTEM SIMULATOR AND A HYBRID GA/SA APPROACH
【24h】

FAULT SECTION ESTIMATION IN POWER SYSTEMS BASED ON A PROTECTION SYSTEM SIMULATOR AND A HYBRID GA/SA APPROACH

机译:基于保护系统模拟器的电力系统故障部分估计和混合GA / SA方法

获取原文

摘要

A Hybrid Genetic Algorithm / Simulated Annealing (HGASA) approach for fault section estimation in power systems based upon the simulation of protection system behaviour is presented. The main work includes the following two aspects: 1. a hybrid optimization method (HGASA) which combines the strengths of Genetic Algorithm (GA) and Simulated Annealing (SA); 2. a new fault section estimation method by the combined use of the HGASA and the simulation of protection system behaviour. In addition, an efficient method for identification of the faulty subnetworks is adopted by using the information from circuit breakers. In this way the fault section estimation can be fulfilled in a very short time even for large scale power systems. Test results for a sample power system have shown that the proposed HGASA method is powerful, and the developed fault section estimation method is very efficient.
机译:提出了一种基于保护系统行为仿真的电力系统故障部分估计的混合遗传算法/模拟退火(HGASA)方法。 主要工作包括以下两个方面:1。结合遗传算法(GA)和模拟退火强度(SA)的混合优化方法(HGASA); 2.一种新的故障段估计方法通过综合使用HGASA和保护系统行为的仿真。 此外,使用来自断路器的信息采用了一种用于识别故障子网的有效方法。 以这种方式,即使对于大规模电力系统,也可以在很短的时间内实现故障部分估计。 样品电力系统的测试结果表明,所提出的HGASA方法是强大的,开发的故障部分估计方法非常有效。