In this paper, circular water pump of a thermal station in Shijiazhuang is taken as the research object of the heating system, whose energy consumption is analyzed. The circular water pump adopts variable frequency speed regulation control, which changes the waste of energy from the previous control system with flow control valve. Along with outdoor temperature change, this paper sets up the mathematical model of the operation adjustment. It is calculated by the analysis: the system can save electricity about 77500 degrees in a heating period. At the same time frequency conversion efficiency can reach 30.88 %, and electricity consumption is only 0.69 of the original heating system. It changes the heating system shortcomings which are low efficiency and big energy consumption before, and improves energy efficiency.
机译:本文采用了石家庄热站的圆水泵作为加热系统的研究对象,其能耗进行了分析。 圆形水泵采用可变频率调节控制,从而从先前的控制系统与流量控制阀改变能量浪费。 随着户外温度变化,本文建立了操作调整的数学模型。 它是通过分析计算的:系统可以在加热时段内节省大约77500度的电力。 在相同的时间频率转换效率可以达到30.88%,电力消耗仅为原始加热系统的0.69。 它改变了低效率和高能耗之前的加热系统缺点,并提高了能量效率。