The present work aims to remove dominant current harmonics (5th,7th,11th and 13th) of a 240V(rms) utility at the point of common coupling for the harmonically unbalanced condition of source current, using parallel combination of two shunt hybrid active filters. The harmonically unbalanced condition of source current has been created by connecting different types of non-linear loads in different phases of the three phase supply i.e. three phase diode bridge rectifier in abc, single phase fully controlled bridge rectifier in phase a & b and single phase ac voltage controller in phase b & c. Due to the different types of non-linear loads connected in the different phases, there are unequal magnitudes of harmonics in different phases thus leading to the harmonic unbalance in the source current. Fourier analysis is used for detection of the desired harmonic from the load current and Sinusoidal Pulse Width Modulation technique has been used to produce gating pulses for the active filter.
机译:目前的工作旨在在源电流的谐波不平衡条件下删除240V(RMS)实用性的主导电流谐波(第5页,第11和第13号),使用两个分流混合有源过滤器的并联组合。通过在ABC中的三相二极管桥式整流器中连接不同的不同类型的不同相位,在ABC中的三相二极管桥式整流器中连接不同类型的非线性负载来创建源电流的谐波不平衡状态。相位B&C中的交流电压控制器。由于在不同阶段连接的不同类型的非线性载荷,因此在不同阶段中存在不等的谐波大小,因此导致源电流中的谐波不平衡。傅里叶分析用于检测来自负载电流的所需谐波,并且正弦脉冲宽度调制技术已经用于产生用于有源滤波器的门控脉冲。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号