首页> 外文会议>International Conference on Electrical Power and Energy Systems >Modified instantaneous p-q theory for single phase DVR for mitigation of voltage sag in case of nonlinear load
【24h】

Modified instantaneous p-q theory for single phase DVR for mitigation of voltage sag in case of nonlinear load

机译:在非线性负载的情况下,改进的单相DVR用于减轻电压凹陷的瞬时P-Q理论

获取原文

摘要

This paper describes the detail study of modified controller based on single phase instantaneous reactive power theory (IRPT) and its application to dynamic voltage restorer (DVR) for both linear and nonlinear load. In this paper systematic study of the controller is presented and suggested an effective control theory for single phase DVR. The controller concept is based on the correction of load voltage without any change in phase. A detailed analysis of modified single phase instantaneous reactive power theory is carried out. The modified controller is based on proportional integral (PI) gains to mitigate single phase voltage sag. The digital simulation of DVR connected single phase system has been performed using MATLAB for both linear and nonlinear load to prove the effectiveness of the modified controller. The simulation results indicates that the proposed controller can restore single phase voltage sag effectively.
机译:本文介绍了基于单相瞬时无功功率理论(IRPT)的改进控制器的细节研究及其在线性和非线性负载的动态电压恢复器(DVR)的应用。在本文中,对控制器进行了系统研究,并提出了单相DVR的有效控制理论。控制器概念基于负载电压的校正,而不会发生任何变化。进行了改进的单相瞬时无功功率理论的详细分析。修改的控制器基于比例积分(PI)增益,以减轻单相电压凹凸。 DVR连接单相系统的数字仿真已经使用MATLAB执行用于线性和非线性负载,以证明修改控制器的有效性。仿真结果表明,所提出的控制器可以有效地恢复单相电压。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号