首页> 外文会议>Symposium on Design, Test, Integration amp;amp;amp;amp;amp;amp; Packaging of MEMS and MOEMS >Analysis of Forces during UV Glue Curing for Micro-Assembly Applications
【24h】

Analysis of Forces during UV Glue Curing for Micro-Assembly Applications

机译:微包装应用UV胶水固化过程中的力分析

获取原文
获取外文期刊封面目录资料

摘要

Positional drift resulted from the glue curing may result into serious challenges towards accuracy especially for micro-assembly processes. Studying forces and positional drifts resulted from the glue curing appears as a key objective towards reaching precise micro-assemblies. For this reason, works notably investigate the forces and displacements originated from the UV glue curing. Experimental investigations demonstrates that the force induced during the glue curing is in 160 μN range against a micro-object with cross section of 500 x 500 μm, and the corresponding positional drift in the 10 μm range was obtained. Works also show that these values depend on the system and strategy used for the assembly.
机译:胶水固化引起的位置漂移可能导致特别是对于微大装配过程的准确性造成严重挑战。胶水固化引起的研究力和位置漂移看起来作为达到精确微组件的关键目标。出于这个原因,显着调查源自UV胶水固化的力和位移。实验研究表明,在胶水固化期间引起的力在160μN抵靠具有500×500μm的横截面的微观物体的范围内,并且获得了10μm范围内的相应位置漂移。 Works还表明这些值取决于用于组装的系统和策略。