The harmonic levels in a distribution system are becoming more important as many new power electronic based devices are being deployed. In order to manage the harmonic levels, it is important to know them. Direct measurement of harmonics at all locations is too costly, yet obtaining a system-wide view is important. Harmonic State Estimation (HSE) is a cost-effective alternative to direct monitoring of all the harmonics. To date, it has been applied mostly to transmission systems but in this paper, it is applied to a model of an actual distribution system. An actual distribution feeder, which is typical of many other feeders in the system is modelled in Open Distribution System Simulator (OpenDSS) and harmonic penetration study performed. Voltage and current harmonics at selected locations are then used as the measurements. Using these measurements and electrical network data, HSE is performed based on a robust mathematical technique, Singular Value Decomposition (SVD). The estimated results are compared with those obtained from harmonic penetration simulations performed in OpenDSS to assess the accuracy of the estimation. Locations and number of measurements that can give maximum observability with reasonable accuracy are also identified.
机译:随着正在部署许多新的电力电子设备,分配系统中的谐波水平变得越来越重要。为了管理谐波水平,了解它们是很重要的。所有地点的谐波直接测量太昂贵,但获得了系统范围的视图很重要。谐波状态估计(HSE)是直接监控所有谐波的经济有效替代方案。迄今为止,它主要用于传输系统,但本文应用于实际分配系统的模型。在系统中的许多其他馈电器中典型的实际分配馈线在开放分配系统模拟器(开放)和谐波渗透研究中进行建模。然后使用所选位置处的电压和电流谐波作为测量值。使用这些测量和电气网络数据,HSE基于稳健的数学技术,奇异值分解(SVD)执行。将估计的结果与在交货中进行的谐波渗透模拟中获得的结果进行比较,以评估估计的准确性。还识别出具有合理精度的最大可观察性的地点和测量次数。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号