According to the main characteristics of boiler operation process, part parameters of boiler and monitoring data, we not only can tease the relationship between various each physical quantity and the influence on the thermal efficiency of the boiler, but also be reasonable parameters and omit the complex on the minimal influence factors of heat loss, finally we use the counter balance calculation method to calculate heat loss, which is mainly aimed at the greatest effect of excess air coefficient, and we consider other major factors that affect the thermal efficiency of the boiler. According to the definition established physical model, the thermal efficiency of the boiler is optimized.
机译:根据锅炉运行过程的主要特点,锅炉和监测数据的部分参数,我们不仅可以挑逗各种物理量之间的关系和对锅炉的热效率的影响,还具有合理的参数,省略复合物 关于热损失的最小影响因素,最后我们使用计数器平衡计算方法来计算热量损失,这主要针对超空气系数的最大效果,我们考虑了影响锅炉热效率的其他主要因素。 根据确定的定义建立的物理模型,优化了锅炉的热效率。