T wave Alternans (TWA) is an important risk identification marker of ventricular arrhythmia and Sudden Cardiac Death (SCD). Number of methods is proposed to detect this micro level phenomenon. The correlation (CM) and modified moving average (MMA) are two time domain, popular and well studied methods. The MMA does not have detection stage but quantification results are good and robust. While the CM has both detection and quantification stages but later is underestimated. Thus considering the shortcomings of each, a new collaborative approach in which detection stage of CM and quantification stage of MMA is proposed. The algorithm is tested on TWA challenge database record. Concordance Correlation Coefficient of 0.41 and 0.70 while RMSE values of 18 and 13 are obtained respectively for CM and MMA. A simple correlation coefficient is almost same for two. Thus the understanding limitations of the existing methods and efforts to overcome those shows value addition and improvement in TWA analysis. This will help to enhance overall prognostic and diagnostic performance of TWA test.
机译:T波动物(TWA)是心间心律失常和突发心脏死亡(SCD)的重要风险鉴定标记。提出了检测这种微水位现象的方法数量。相关性(CM)和修改的移动平均(MMA)是两个时域,流行且研究的方法。 MMA没有检测阶段,但定量结果是良好和稳健的。虽然CM具有检测和量化阶段,但后来被低估了。因此,提出了一种提出了一种新的协同方法,其中提出了一种新的协作方法,其中CM和MMA的量化阶段的检测阶段。该算法在TWA挑战数据库记录上进行了测试。同时分别获得CM和MMA的RMSE值为0.41和0.70的一致性系数0.41和0.70。两个简单的相关系数对于两个几乎相同。因此,了解现有方法和努力克服这些方法的限制显示了TWA分析的价值添加和改进。这将有助于提高TWA测试的整体预后和诊断性能。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号