摘要

This paper work suggests a Discontinuous Pulse Width Modulation (DPWM) technique to eliminate the Common Mode Voltage (CMV) for a dual two-level inverter fed Open End Winding Induction Motor (OEWIM) feeding from a single PV source. The ill effects of CMV such as sparking at bearing due to the shaft voltage and electromagnetic interference at higher switching frequency are dealt with. Hence the system becomes more reliable. This technique provides lower switching losses compared to continuous PWM methods. The proposed stand-alone system is used to drive a centrifugal pump. The overall performance of the proposed configuration have been verified using MATLAB/Simulink. And from the result it is found that centrifugal pump is a well suited drive for such a stand-alone system.
机译:本文作品表明,不连续的脉冲宽度调制(DPWM)技术,以消除来自单个PV源的双重双电平逆变器的共模电压(CMV),从单个PV源供给馈电开口端绕组感应电动机(OEWIM)。 CMV的效果如轴电压和较高开关频率的电磁干扰引起的轴承引发。因此系统变得更加可靠。与连续PWM方法相比,该技术提供了较低的开关损耗。所提出的独立系统用于驱动离心泵。使用MATLAB / SIMULINK验证了所提出的配置的整体性能。从结果,发现离心泵是这种独立系统的良好驱动。