This report describes investigations and actions on a 500-kV transmission line operated by the US utility Salt River Project (SRP) and initiated by new considerations regarding the transmission lines' reliability program by the US North American Electric Reliability Corporation (NERC). Based on NERC's new system clearance requirements for certain switching surge overvoltage levels, SRP decided to apply high energy transmission line arresters (TLAs) for limiting those overvoltages to levels that would avoid the need for much more expensive capital improvements to increase clearance to ground, for example to replace or enlarge the tower construction. The correct location of the TLAs and the line span to be protected were determined by a software study by analyzing transmission line energization overvoltages for different cases. The utility and the arrester manufacturer jointly decided about the design of the surge arrester to be developed, a high strength polymer housed station class surge arrester with high energy handling capability of 13 kJ·kVMCOV−1. As agreed between SRP and the manufacturer, the energy rating test was repeated by Siemens per the latest IEEE/ANSI std. C62.11-2012.
机译:这份报告描述了美国实用盐河项目(SRP)的,由有关美国北美电力可靠性公司(NERC)的传输线的可靠性节目新的考虑启动了500千伏输电线路的调查和行动。基于NERC的新系统清算要求对某些交换浪涌过电压水平的要求,SRP决定应用高能量传输线避雷器(TLA),以限制这些过电压,以避免需要更昂贵的资本改进来增加地面的间隙。替换或放大塔楼的示例。通过分析不同情况的传输线通电过电压,通过软件研究确定TLA的正确位置和要保护的线路跨度。该实用程序和避雷器制造商共同决定有关避雷器的设计待开发的高强度聚合物容纳站类的电涌放电器具有高能量处理13千焦·kVMCOV-1的能力。根据SRP和制造商之间的商定,每次最新IEEE / ANSI STD的西门子重复了能源评级测试。 C62.11-2012。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号