首页> 外文会议>International conference on nano science and technology >A Renewable Amperometric Immunosensor for hs-CRP Based on Functionalized Fe3O4@Au Magnetic Nanoparticles Attracted on Fe(III) Phthlocyanine/Chitosan-membrane Modified Screen-printed Carbon Electrode By A Magnet
【24h】

A Renewable Amperometric Immunosensor for hs-CRP Based on Functionalized Fe3O4@Au Magnetic Nanoparticles Attracted on Fe(III) Phthlocyanine/Chitosan-membrane Modified Screen-printed Carbon Electrode By A Magnet

机译:基于官能化Fe3O4的HS-CRP的可再生排水素免疫传感器在Fe(III)酞菁/壳聚糖 - 膜通过磁体上被吸引的磁性纳米粒子被吸引

获取原文

摘要

A novel disposable screen-printed immunosensor for rapid determination of highly sensitive C reactiveprotein (hs-CRP) in human serum has been developed in the experiment The sensor was constructed on one screen-printed carbon electrode (SPCE) with HRP labeled anti-hs-CRP antibody functionalized Fe3O4@Au magnetic nanoparticles (HRP labeled anti hs-CRP/Fe3O4@Au) as the biorecognition probes attracted on the surface of Fe (III) phthalocyanine (FePc)/chitosan membrane modified screen-printed carbon electrode (SPCE|FePc/Chit/chitosan) by external magnetic field. FePc was acted as electron immediate. The modified electrode shows an excellent electrocatalytic activity for hs-CRP in phosphate buffer solution (pH=7.0). After the immunosensor is incubated with hs-CRP antigen solution at 37°C for 20 min, the access of activity center of the HRP to electrode is partly inhibited, which leads to a linear decrease of the catalytic efficiency of the HRP to the reduction of immobilized FePc by H2O2 at -SO mV in hs-CRP's concentration ranges from 1.2 to 200 ng/mL. The detection limit was 0.5 ng/mL. The immunosensor was successfully utilized for determination of hs-CRP in real serum samples of heart disease patients, whose results were consistent with that by ELISA method. The accuracy and precision of the assay were 91.5104.4% and 15.8-24.4%, respectively. The immunosensor was reusable once constructed and can be regenerated by adding new nanoprobes on the surface of basal electrode through magnet on its bottom. It can greatly reduce the detection cost which is valuable for the early diagnosis of tumors.
机译:在实验中开发了一种用于快速测定人血清中高敏感的C反应蛋白(HS-CRP)的新型一次性丝网印刷免疫传感器在一个屏幕印刷的碳电极(SPCE)上构建了HRP标记的抗HS- CRP抗体官能化Fe3O4官能化Fe3O4磁性纳米颗粒(HRP标记的抗HS-CRP / Fe3O4 @ Au)作为在Fe(III)酞菁(FEPC)/壳聚糖膜改性丝网印刷碳电极(SPCE | FEPC | FE)上吸引的生物认知探针/ Chit /壳聚糖)通过外部磁场。 FEPC被担任电子即时。改性电极显示出在磷酸盐缓冲溶液中的HS-CRP的优异电催化活性(pH = 7.0)。在37℃下与HS-CRP抗原溶液一起温育20分钟后,部分抑制HRP与电极的活性中心的进入,这导致HRP催化效率的线性降低到减少在HS-CRP的浓度下将FEPC固定为H 2 O 2的浓度为1.2至200ng / ml。检出限为0.5ng / ml。免疫传感器已成功用于测定心脏病患者的真正血清样本中的HS-CRP,其结果与ELISA方法一致。测定的准确性和精度分别为91.5104.4%和15.8-24.4%。一旦构造,免疫传感器可重复使用,并且可以通过在其底部通过磁体在基底电极的表面上添加新的纳米体进行再生。它可以大大降低对肿瘤早期诊断有价值的检测成本。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号