首页> 外文会议>IEEE International Conference on Power System Technology >Research on Ferromagnetic Resonance Principle and Harmonic Elimination Measures in Distribution Network
【24h】

Research on Ferromagnetic Resonance Principle and Harmonic Elimination Measures in Distribution Network

机译:配电网铁磁共振原理及谐波消除措施研究

获取原文

摘要

In the ungrounded neutral network, the ferromagnetic resonance caused by the saturation of the electromagnetic voltage transformer is more likely to occur. The ferromagnetic resonance seriously threatens the safe and stable operation of the power grid and can be maintained for a long time. in this paper, the mechanism of the generation of ferromagnetic resonance in the ungrounded neutral network is first studied, the transient mechanism of the formation of ferromagnetic resonance is analyzed, and through the Krylov and Bogoliubov algorithm, the approximate solution of the transient voltage and transient excitation current of the primary side of the voltage transformer is obtained, The damping harmonic elimination is proved to be a more effective method of harmonic elimination. then the ferromagnetic resonance model of the distribution network is built, and the correctness of the theoretical analysis is verified by three typical harmonic elimination measures. The simulation results show that the damping harmonic elimination method is more effective and faster than the method of destroying the resonant parameters.
机译:在未接地的中性网络中,更容易发生由电磁电压变压器的饱和引起的铁磁共振。铁磁共振严重威胁到电网的安全稳定运行,可以长时间保持。在本文中,首先研究了未接地中性网络中铁磁共振的机理,分析了铁磁共振形成的瞬态机制,通过Krylov和Bogoliubov算法,瞬态电压和瞬态的近似解获得电压变压器的初级侧的激励电流,证明阻尼谐波消除是更有效的谐波消除方法。然后建立了分配网络的铁磁共振模型,并通过三种典型的谐波消除措施来验证理论分析的正确性。仿真结果表明,阻尼谐波消除方法比破坏谐振参数的方法更有效且更快。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号