首页> 外文会议>International Conference on Solar Energy for Buildings and Industry >EXPERIMENTAL ANALYSIS OF LATENT THERMAL ENERGY STORAGE CHARGING AND DISCHARGING
【24h】

EXPERIMENTAL ANALYSIS OF LATENT THERMAL ENERGY STORAGE CHARGING AND DISCHARGING

机译:潜热储能充放电实验分析

获取原文

摘要

Experimental investigation of latent thermal energy storage (LTES) charging and discharging has been performed. The LTFS unit is a shell-and tube type tank with water as the heat transfer fluid (HTF). which flows through the tubes, and technical grade paraffin RT 25 as the phase change material (PCM), filling the shell side. The total of 19 longitudinally finned tubes are arranged concentrically in the tank. A set of 30 thermocouples have been placed at various radial and axial positions on the PCM side for monitoring transient temperature variations during charging and discharging processes. Timewise temperature variations of PCM during charging and discharging, for different HTF inlet temperatures, have been presented. Stored and released thermal energy have been calculated and analyzed.
机译:对潜热储能(LTES)充放电进行了实验研究。LTFS单元是一个管壳式储罐,以水为传热流体(HTF)。它流经管子,技术级石蜡RT 25作为相变材料(PCM),填充壳侧。水箱内共有19根纵向翅片管同心布置。在PCM侧的不同径向和轴向位置放置了一组30个热电偶,用于监测充电和放电过程中的瞬态温度变化。介绍了不同HTF入口温度下,PCM在充放电过程中的时间温度变化。对储存和释放的热能进行了计算和分析。