This document explicates the improvisations made to overcome the startup failures due to hardware limitations of Urea Plant at Engro Fertilizers Limited, Pakistan. Since plant commissioning, the success rate of the Urea plant startup has been low because of instability of the high pressure scrubber U-seal which also results in ammonia pollution & excessive venting. Startups experienced during the operating period of more than 20 years have been listed. Each scenario was studied with thorough Root Cause Analysis, resulting in identification and implementation of process variations. These changes resulted in improved startup success rate and reduced startup time. This eventually helped in minimizing the excessive venting and therefore eliminated environmental concerns which ultimately facilitated Engro to keep their promise of Clean & Pollution Free Environment.
机译:本文件阐述了克服启动失败所作的即兴创作失败,因为垃圾肥料有限公司,巴基斯坦尿素厂的硬件限制。由于植物调试,由于高压洗涤器U密封的不稳定性,尿素厂启动的成功率较低,这也导致氨污染和过度通风。已列出在20多年的运营期间经验丰富的初创公司。通过彻底的根本原因分析研究了每种情况,导致识别和实施过程变化。这些变化导致启动成功率提高并减少了启动时间。这最终有助于最大限度地减少过度通风,因此消除了最终促进了垃圾的环境问题,以保持他们对清洁和无污染环境的承诺。