首页> 外文会议>IIR International Conference on Thermophysical Properties and Transfer Processes of Refrigerants >HFC404A CONDENSATION INSIDE A 4MM HORIZONTAL SMOOTH TUBE: COMPARISON WITH THE LONG-TERM LOW GWP SUBSTITUTES HC290 (PROPANE) AND HC1270 (PROPYLENE)
【24h】

HFC404A CONDENSATION INSIDE A 4MM HORIZONTAL SMOOTH TUBE: COMPARISON WITH THE LONG-TERM LOW GWP SUBSTITUTES HC290 (PROPANE) AND HC1270 (PROPYLENE)

机译:HFC404A冷凝4mm水平光滑管:与长期低GWP替代HC290(丙烷)和HC1270(丙烯)的比较

获取原文

摘要

This paper presents the comparative analysis of HFC404A and its low GWP substitutes HC290, and HC1270 in saturated vapour condensation inside a 4 mm ID horizontal smooth tube. The experimental tests were carried out at 30, 35, and 40°C of saturation temperatures, with refrigerant mass flux in the range 75 - 800 kg m~(-2)s~(-1) at decreasing vapour quality. A transition point from gravity-dominated and forced convection condensation was found for an equivalent Reynolds number around 10000. The experimental heat transfer coefficients in the forced convection condensation regime were very well predicted by the Akers et al. (1959) model, whereas the Friedel (1979) correlation was able to reproduce the frictional pressure drop data in the whole experimental range. HC290 and HC1270 exhibit heat transfer coefficients higher and frictional pressure drops lower than those of HFC404A; therefore both the HC refrigerants seem to be very promising as long-term low GWP substitutes for HFC404A.
机译:本文介绍了HFC404A及其低GWP替代HC290的对比分析,以及在4mm ID水平光滑管内的饱和蒸汽冷凝中的HC1270。实验试验在30,35和40℃下进行饱和温度,在蒸汽质量下的75-800kg m〜(-2)〜(-1)范围内的制冷剂质量通量。从重力主导和强制对流冷凝的过渡点被发现为约10000左右的等效雷诺数。强制对流冷凝制度中的实验热传递系数由Akers等人预测。 (1959)模型,而Friedel(1979)相关性能够在整个实验范围内再现摩擦压力下降数据。 HC290和HC1270表现出热传递系数较高,摩擦压低低于HFC404A的压力下降;因此,HC制冷剂似乎非常有前途,因为HFC404a的长期低GWP替代品。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号