At the Kemi Mine, a recent expansion into the Surmaoja orebody required an increase in ventilation capacity. A new ventilation shaft was built with two main fans. The installation is near the entrance gate and only 1.7 kilometres from the nearest permanent dwelling. The main fans were first taken into use as exhaust fans in October 2014. Shortly after the fan installation, comments concerning fan noise were received from the neighbours. The first noise measurements were taken at the main fan installation site by Outokumpu personnel in March 2015. Due to higher than expected recorded values, during late June, 2015, a two-week environmental noise study was planned by the engineers and executed by a consultant specialized in noise measurement. The measurement results were analysed and compared to the requirements of the environmental permit and Outokumpu's factory standards. While the measured values at the nearest dwelling were within the environmental permit limits, high noise values were recorded at the fan station. A second two-week study will be performed after construction of the main-fan heating station has been completed. Actions taken will depend on the outcome.
机译:在Kemi Mine,最近进入Surmaoja Orebody的扩张需要增加通风能力。新的通风轴采用两个主要风扇建造。安装靠近入口门,距离最近的永久性住宅仅1.7公里。主要粉丝首次于2014年10月被用作排气扇。风扇安装后不久,从邻居收到了有关风扇噪声的评论。 2015年3月由Outokumpu人员在主风扇安装现场拍摄的第一次噪声测量。由于录制价值高于预期,2015年末,工程师计划由一项为期两周的环境噪声研究,并由顾问执行专门的噪声测量。分析测量结果并与环境许可证和Outokumpu的工厂标准的要求进行了比较。虽然最近住宅的测量值在环境许可证内,但在风扇站记录了高噪声值。在建造主风扇加热站完成后,将进行第二两周的研究。采取的行动取决于结果。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号