Performance response tests on a multivariable fuzzy rule-based relay for short circuits in AC micro-grids

机译:AC微电网中短路的多变模糊规则的性能响应测试

获取原文

摘要

This paper presents the results of offline and online performance tests on a new multivariable fuzzy rule-based (MFR) relay for AC micro-grids. The relay is based on measurement of four critical parameters (P, Q, V and I) and fuzzy logic implementation of rules framed on the basis of these parameters. The online test is performed by embedding the relay in a micro-grid test bed capable of grid-connection. The offline test is performed by simulating High, Normal and Low states of the four parameters using proper combination of digital signal sources to implement short circuits (SCs) in SIMPOWERSystems? software. In both offline and online tests, the faults simulated are standard SCs in the utility and micro-grid. The results of both offline and online tests are similar, and show that the MFR relay outputs logic 1 during SC faults. The relay also outputs logic 0 before and after the SC faults for both offline and online tests.
机译:本文介绍了对AC微电网的新多变量模糊规则(MFR)继电器的离线和在线性能测试的结果。继电器基于测量四个关键参数(p,q,v和i)和基于这些参数的规则的模糊逻辑实现。通过将继电器嵌入能够进行网格连接的微网测试床中来执行在线测试。通过使用数字信号源的适当组合来模拟四个参数的高,正常和低状态来执行离线测试来执行SimPowersystems中的短路(SCS)吗?软件。在离线和在线测试中,模拟的故障是实用程序和微网格中的标准SCS。离线和在线测试的结果是相似的,并显示MFR继电器在SC故障期间输出逻辑1。继电器还在SC故障之前和之后输出逻辑0,用于离线和在线测试。