In order to maintain the high system energy efficiency, the heat imbalance problem in soil around the ground heat exchangers (GHE) should be avoid for the hybrid ground coupled heat pump (HGCHP) technology by rejecting the unbalanced heat through the supplemental heat rejecter. Since cooling towers are normally used as supplemental heat rejecters of the HGCHP system and few detailed experimental results are reported, the cooling performance of HGCHP system with cooling tower services as supplemental heat rejecter is investigated with experimental method in this study. A HGCHP system test rig with comprehensive data acquisition equipment is reported, and detailed on-site experiments on this test rig operated with different control strategies for cooling provision is carried out. Based on investigation, the optimal control strategy and control parameter for cooling provision is proposed by comparing the practical operation performance of the HGCHP system.
机译:为了保持高系统能量效率,通过通过补充热回收器拒绝不平衡的热量来避免接地热交换器(GHE)周围的土壤中的热不平衡问题。 由于冷却塔通常用作HGCHP系统的补充热回收器,并且报告了很少的详细实验结果,因此通过本研究的实验方法研究了作为补充热回收器的冷却塔服务的HGCHP系统的冷却性能。 报道了一种具有综合数据采集设备的HGCHP系统试验台,并进行了在该试验台上进行了详细的现场实验,采用不同控制策略进行冷却策略。 基于调查,通过比较HGCHP系统的实际操作性能,提出了用于冷却提供的最佳控制策略和控制参数。