首页> 外文会议>Conference on MOEMS and miniaturized systems XIV >Improvement of Varioptic's liquid lens based on electrowetting: how to obtain a short response time and its application in the design of a high resolution iris biometric system
【24h】

Improvement of Varioptic's liquid lens based on electrowetting: how to obtain a short response time and its application in the design of a high resolution iris biometric system

机译:基于电润湿的Varioptic液体镜头的改进:如何在高分辨率虹膜生物识别系统设计中获得短响应时间及其应用

获取原文

摘要

This communication presents the results obtained for decreasing the response time of electrowetting-based real time focus correctors (liquid lenses). In order to provide a compact iris biometric system demonstrator, we have achieved a response time at 90% of 7.5 ms for a change in focalization from 0 diopter to 10 diopter with a liquid lens having an aperture of 1.9 mm. We have used a hydrodynamic fluid reorganization model to predict the features of these fast liquid lenses and evaluated the sensivity of the response time to the different conception parameters.
机译:该通信呈现了用于减少基于电润湿的实时焦点校正器(液体镜片)的响应时间的结果。为了提供紧凑型虹膜生物识别系统演示,我们已经实现了70%的响应时间,占7.5ms的90%,以便从0屈光度到10分屈光度的聚焦化变化,液体透镜具有1.9mm的孔透镜。我们使用了流体动力学液体重组模型来预测这些快液透镜的特征,并评估响应时间与不同概念参数的感觉。