首页> 外文会议>International Conference on Civil, Materials and Environmental Sciences >In-Situ Monitoring of the Effect of External Environment on a Contemporary Building in Prague: The Performance of the Additional Thermal Insulation System
【24h】

In-Situ Monitoring of the Effect of External Environment on a Contemporary Building in Prague: The Performance of the Additional Thermal Insulation System

机译:原位监测外部环境对布拉格当代建筑的影响:额外的隔热系统的性能

获取原文

摘要

Experimental assessment of the hygrothermal performance of an office building in Prague, which was recently provided by an additional contact thermal insulation system (TIS), is done in the paper, in order to evaluate the contribution of the applied TIS to the moderation of the interior climate. At the long-term in-situ analysis of the building, the measurement of relative humidity and temperature profiles along the cross section of a selected part of the building envelope is carried out. The measurement is realised for 1.5 year on the non-insulated wall at first, and after the application of the exterior TIS it continues for another 1 year. The obtained results show an improvement in the hygrothermal function of the analysed building envelope due to the application of TIS that reduces significantly the thermal response of the investigated building to the changes of environmental conditions.
机译:实验评估布拉格办公楼的湿热性能,最近由额外的接触保温系统(TIS)提供,以评估所施加的TIS对内部的适度的贡献 气候。 在建筑物的长期原位分析中,进行沿着建筑包络的所选部分的横截面测量相对湿度和温度曲线。 首先在非绝缘墙上实现了1.5年的测量,并且在外部施加后,它持续1年。 所获得的结果表明,由于TIS的应用,分析的建筑物包络的湿热功能提高了调查建筑物对环境条件的变化的显着降低。