首页> 外文会议>ASNT Annual Conference >The Use of Full Matrix Capture and Software Beam Forming for Reduced Inspection Times
【24h】

The Use of Full Matrix Capture and Software Beam Forming for Reduced Inspection Times

机译:使用全矩阵捕获和软件光束形成减少检查时间

获取原文

摘要

Typical implementations of the full matrix capture technique (FMC) of ultrasonic inspection are slow and computationally expensive. As such, the technique has gained the reputation of being a "science experiment" or "lab curiosity". Three factors which lead to this slowness are limited data throughput, limited processing power, and fundamental (ultrasonic) limitations of data collection. Moreover, typical implementations of matrix capture inspections lead to results that are not directly comparable with those produced by monolithic or phased-array inspections.
机译:超声波检查的全矩阵捕获技术(FMC)的典型实现是缓慢和计算昂贵的。 因此,该技术已获得“科学实验”或“实验好奇心”的声誉。 导致这种缓慢的三个因素是数据吞吐量有限,有限的处理能力和基本收集的基本(超声波)限制。 此外,基质捕获检查的典型实现导致与通过单片或分阶段阵列检查产生的结果不直接比较。