首页> 外文会议>Hydrovision International Conference and Exhibition >THOMPSON FALL UNIT 7 STATOR CORE BOLT FAILURE SEPTEMBER 2004
【24h】

THOMPSON FALL UNIT 7 STATOR CORE BOLT FAILURE SEPTEMBER 2004

机译:汤普森秋季单位7定子芯螺栓故障2004年9月

获取原文

摘要

On September 21, 2004 during a routine generator inspection two broken core bolts with nuts were found lodged into the back of the generator stator coils. Further inspection by ultrasound technology determined that 40 bolts total were cracked which was 20% of the total. This presentation will cover the subsequent investigation including the temporary fix and then cover the permanent fix. It will also include testing done to verify the failure and also to test the resulting repair.
机译:2004年9月21日在常规发生器检查期间,发现两个破碎的芯螺栓被发现留在发电机定子线圈的背面。 通过超声技术进一步检查确定总共40个螺栓裂解,占总含量的20%。 此演示文稿将涵盖随后的调查,包括临时修复,然后涵盖永久性修复。 它还将包括进行测试,以验证故障以及测试结果修复。