Instant and solid corrosion diagnosis on reinforced concrete structures with galvanostatic pulse measurement

机译:钢筋静压脉冲测量钢筋混凝土结构的瞬间与固体腐蚀诊断

获取原文

摘要

The potential survey has established itself as the major NDT measurement for the assessment of rebar corrosion on concrete structures. Although it is easy to obtain the data, its correct interpretation is difficult and sometimes impossible, as the intended indicators for corrosion will be overlaid by varying concrete humidity, concrete cover and concrete composition to an unknown extent. Very often, a correlation with chloride values sampled from suspect areas will not result in a feasible pattern for the evaluation of the corrosion activity. With the help of enhanced corrosion measurement methods, such as impedance- and galvanostatic pulse measurements, these uncertainties can be eliminated safely in most cases. Furthermore, also carbonation induced corrosion -where potential mapping provides no access basically - can be evaluated securely.
机译:潜在的调查已经成为关于在混凝土结构上评估钢筋腐蚀的主要NDT测量。尽管很容易获得数据,但其正确的解释是困难的,有时不可能,因为腐蚀的预期指示器将通过不同的混凝土湿度,混凝土盖和混凝土组合物在未知程度上覆盖。通常,与嫌疑人区域采样的氯化物值的相关性不会导致可行的模式以评估腐蚀活动。借助于增强的腐蚀测量方法,例如阻抗和镀锌脉冲测量,可以在大多数情况下安全地消除这些不确定性。此外,碳化诱导的腐蚀 - 当时潜在的映射不提供任何访问基本上 - 可以安全地评估。