摘要

An advanced experimental rig for heat pump water heaters was established. The performances of both a phase-change heat-storage-type heat pump water heater (Type A) and a conventional heat pump water heater (Type B) were tested and compared according to GB/T 23137-2008 using the experimental rig. The results showed that the existence of phase transition temperature platform enabled the phase-change heat-storage-type heat pump heater run longer and more steadily. When the same hot water heat capacity obtained, the volume of the accumulator in the Type A water heater accounted for about 56.9% of that of the water tank in the Type B water heater, which could save the overall size of water heater significantly and therefore promote the wide application of energy-saving heat pump water heaters.
机译:建立了一种用于热泵热水器的先进的实验钻机。 通过使用实验钻机对相变储热型热泵热泵(A型)和传统的热泵热水器(型B)进行比较,并将其进行比较。 结果表明,相变温度平台的存在使得相变储热型热泵加热器较长,更稳定地运行。 当获得相同的热水热量时,水加热器中蓄电池的体积占B型热水器中的水箱中的约56.9%,这可以显着挽救热水器的总体尺寸 促进节能热泵热水器广泛应用。