THE COMPARISON OF EXPERIMENT RESULTS AND CFD SIMULATION IN THE HEAT PUMP SYSTEM USING THERMOBANK AND TWO PHASE EJECTOR FOR HEATING ROOM AND COLD STORAGE

机译:热泵系统中实验结果和CFD仿真的比较,采用热水泵和两相喷射器加热室和冷藏

获取原文

摘要

In this paper, heat pump system has been developed by CFD simulation and experimental investigation. The two phase ejector is used in system which is increase in coefficient of performance (COP) and decrease in compressor displacement relative to a standard vapor compressor cycle. The thermobank stores the wasted heat of during refrigeration cycles and its energy is used for defrosting process and heating room. It also reduces defrosting time and condensation load so that the temperature regulation in the cold storage is stable. The COP increases about 38.57% with experiment and 42.7% with simulation when the thermobank and ejector are installed in heat pump system. In general, the simulated and experimental results of heat pump system using thermobank and ejector show good agreement. This heat pump system can be used to keep preservation of agricultural products in cold storage warehouse together with floor panel heating for room in winter.
机译:本文采用CFD仿真和实验研究开发了热泵系统。 两个相喷射器用于系统中的性能系数(COP)增加,并相对于标准蒸汽压缩机循环减小压缩机位移。 Thermobank在制冷循环期间储存浪费的热量,其能量用于除霜过程和加热室。 它还减少了除霜时间和冷凝载荷,使冷藏中的温度调节稳定。 COP随着Thermobank和喷射器安装在热泵系统中时,COP随着实验和42.7%增加了42.7%。 一般来说,使用Thermobank和喷射器的热泵系统的模拟和实验结果表明良好的一致性。 该热泵系统可用于保存冷藏仓库中的农产品,以及冬季室内的地板电热。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号