Centre de la Manche disposal facility is the first French surface disposal facility dedicated to low and intermediate level short lived radioactive waste. It started up in 1969. After a continuous improvement, in the design of disposal vaults, in operational modes, in the whole process of waste management, in the safety approach, the last packages were received in 1994. 527,000 m~3 of waste packages have been disposed during the 25 years of operation. The facility was licensed for the institutional control period in 2003. The disposal vaults are covered with a multilayer capping system that includes a bituminous membrane to provide protection against rainwater infiltration. Water that might infiltrate through the membrane is collected by the bottom slab of the vaults to a pipe network implemented in an underground gallery. Measurements show an overall infiltration rate of about 3 l/m~2/year that complies with the objective of Andra of a few liters per square meter and per year. Investigations are performed in order to assess the behavior of the membrane in the long term. For this purpose periodically samples of the bituminous membrane are taken and measurements are performed. As at the beginning of the operational period waste packages were not conditioned in accordance with the specifications that are presently prescribed to waste generators, some settlements can be observed on the ancient part or the facilities. At the end of 2009 some excavation works were performed in an area where a settlement of few tens of centimeters was observed. The integrity of the membrane could be observed and the adequacy of the selection of this option for the watertightness of the capping system was so confirmed. Environmental monitoring includes radiological and chemical measurements for discharge, underground water and surface water. In the particular framework of Centre de la Manche, a contamination of groundwater by tritiated wastes occurred in 1976. Theses wastes were removed in 1977 and 1978 but tritium can still be detected under the facility. However the impact to a hypothetical critical group, using only local water, is presently about 0,4 μSv per year (2009). A safety review of the facility was performed in 2009 by the regulatory body. It was noticed that the behavior of the facility was consistent with predictions. The progressive strategy proposed by Andra to improve the capping system, in particular to achieve long term stability of the slopes, was assessed. The process implemented by Andra to maintain memory of the facility was discussed. In this way the periodical safety reviews are part of the dynamic process through which the monitoring of the facility will become progressively more and more passive.
机译:Center de La Manche处理设施是第一个致力于低且中级短期的放射性废物的法国表面处理设施。它于1969年开始。在持续改进之后,在处理拱顶的设计中,在运营模式下,在废物管理的整个过程中,在安全方法中,上一揽子收到了1994年。527,000 M〜3的废物包装已在25年的运作期间处置。该设施于2003年为机构控制期获得了许可。使用包括沥青膜的多层封盖系统覆盖了处置拱顶,以提供防止雨水渗透的保护。可能通过膜渗透的水通过拱顶的底板收集到在地下画廊中实现的管道网络。测量显示总体渗透率约为3L / m〜2 /年,符合每平方米和每年几升的八升的目标。进行调查,以便在长期评估膜的行为。为此目的,粉末膜的定期样品进行并进行测量。由于在运营时期的开始,废物包没有按照目前规定的规格调节废物发电机,可以在古代部分或设施上观察到一些居所。在2009年底,一些挖掘工程在观察到几十厘米的结算的区域中进行。如此证实,可以观察到膜的完整性,并且对封端系统的水密性选择选择这种选择的充分性。环境监测包括放电,地下水和地表水的放射学和化学测量。在Center de La Manche中心的特定框架中,1976年通过氚介绍的地下水污染。1977年和1978年,除了氚的废物,但仍可在该设施下检测氚。然而,仅使用当地水的假设关键群的影响目前每年约为0,4μV(2009)。该设施的安全审查由监管机构于2009年进行。注意到设施的行为与预测一致。评估了ANDRA提出的渐进策略,特别是为了改善覆盖系统,特别是实现斜坡长期稳定性。讨论了安德拉实施的过程以维持设施的记忆。通过这种方式,期刊安全审查是动态过程的一部分,通过该过程通过该过程通过该过程通过该过程通过该过程,该工厂的监测将逐渐变得越来越多。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号