首页> 外文会议>International Conference on Civil Engineering, Architecture and Building Materials >The Research of Test on Load-Bearing Capacity of the New Energy-Saving Panels
【24h】

The Research of Test on Load-Bearing Capacity of the New Energy-Saving Panels

机译:新节能面板承载能力试验研究

获取原文

摘要

According to transverse load test on two half-scale energy-saving wall panels with different space. It is analyzed these panels with failure processes, failure modes, ultimate bearing capacity, load-deflection curves, concrete load-strain curves and steel load-strain curves. The results show that failure modes, flexural stiffness and ultimate strength of panels are affected by ratio of steel.
机译:根据具有不同空间的两个半尺度节能壁板上的横向载荷试验。 通过故障过程,故障模式,最终承载能力,载荷偏转曲线,混凝土负载 - 应变曲线和钢负载 - 应变曲线分析了这些面板。 结果表明,面板的失效模式,弯曲刚度和极限强度受钢幂的影响。