首页> 外文会议>International Conference on Energy and Environmental Protection >Analysis and Precautionary measures for T23 Steel Water Wall Leakage of 1000 MW Ultra-supercritical Tower Boiler
【24h】

Analysis and Precautionary measures for T23 Steel Water Wall Leakage of 1000 MW Ultra-supercritical Tower Boiler

机译:1000 MW超超临界塔锅炉T23钢水壁泄漏分析与预防措施

获取原文

摘要

Taking the case of the T23 steel water wall leakage in a 1000 MW ultra-supercritical tower boiler as an example, the reasons why the T23 steel water wall leakage of this type tower boiler may take place easily were analyzed from several aspects such as the material characteristics of T23 steel, the jointing and welding technology, the heat sensitivity of water walls and the rationality of operating ways. Then the measures to decrease water wall leakage were brought in, which improved the operating security of the tower boiler.
机译:以1000兆瓦超超临界塔锅炉泄漏的情况为例,作为示例,可以从诸如材料等若干方面分析这种塔式锅炉T23钢水堵塞的原因。 T23钢的特点,焊接技术,水墙的热敏性及经营方式的合理性。然后提出了减少水壁泄漏的措施,改善了塔式锅炉的操作安全性。