首页> 外文会议>SPIE Conference on Physics of Medical Imaging >Effect of contrast magnitude and resolution metric on noise-resolution tradeoffs in x-ray CT imaging: a comparison of non-quadratic penalized alternating minimization and filtered backprojection algorithms
【24h】

Effect of contrast magnitude and resolution metric on noise-resolution tradeoffs in x-ray CT imaging: a comparison of non-quadratic penalized alternating minimization and filtered backprojection algorithms

机译:对比度幅度和分辨率度量对X射线CT成像中噪声分辨率权衡的影响:非二次惩罚交替最小化和滤波反扩展算法的比较

获取原文

摘要

Purpose: To assess the impact of contrast magnitude and spatial resolution metric choices on the noise-resolution tradeoff of a non-quadratic penalized statistical iterative algorithm, Alternating Minimization (AM), in x-ray transmission CT. Methods: Monoenergetic Poisson-counting CT data were simulated for a water phantom containing circular inserts of varying contrast (7% to 238%). The data was reconstructed with conventional filtered backprojection (FBP) and two non-quadratic penalty parameterizations of AM. A range of smoothing strengths is reconstructed for each algorithm to quantify the noise-resolution tradeoff curve. Modulation transfer functions (MTFs) were estimated from the circular contrast-insert edges and then integrated up to a cutoff frequency as a single-parameter measure of local spatial resolution. Two cutoff frequencies and two resolution comparison values are investigated for their effect on reported tradeoff advantage. Results: The noise-resolution tradeoff curve was always more favorable for AM than FBP. For strongly edge-preserving penalty functions, this advantage was found to be dependent upon the contrast for which resolution is quantified for comparison. The magnitude of the reported dose reduction potential of the AM algorithm was shown to be dependent on the resolution metric choices, though the general contrast-dependence was always evident. Conclusions: The penalized AM algorithm shows the potential to reconstruct images of comparable quality using a fraction of the dose required by FBP. The contrast-dependence on the tradeoff advantage implies that statistical algorithms using non-quadratic penalty functions should be assessed using contrasts relevant to the intended clinical task.
机译:目的:评估对比度幅度和空间分辨率选择对非二次惩罚统计迭代算法的噪声分辨率权衡的影响,在X射线传输CT中交替最小化(AM)。方法:对含有不同对比度的圆形插入物的水体模拟单元泊位计数CT数据(7%至238%)。通过传统的过滤的反调(FBP)和两个非二次惩罚参数来重建数据。为每种算法重建一系列平滑强度以量化噪声分辨率的折衷曲线。从圆对比度插入边缘估计调制传递函数(MTFS),然后将截止频率集成为局部空间分辨率的单个参数测量。为他们对报告的权衡优势进行了影响,研究了两个截止频率和两个分辨率的比较值。结果:噪声分辨率的权衡曲线总是比FBP更有利。对于强烈保持惩罚功能,发现该优点是依赖于量化分辨率进行比较的对比度。据报道的AM算法的报告剂量降低电位的幅度被显示为取决于分辨率度量选择,尽管始终依赖依赖性始终是显而易见的。结论:惩罚的AM算法显示了使用FBP所需的剂量的一部分重建可比质量的图像的可能性。对求权优势的对比度依赖意味着应使用与预期临床任务相关的对比度来评估使用非二次惩罚功能的统计算法。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号