首页> 外文会议>International Conference on Structures and Building Materials >Floating Roof Influence on Seismic Response of Large Vertical Storage Tank
【24h】

Floating Roof Influence on Seismic Response of Large Vertical Storage Tank

机译:浮屋顶对大型垂直储罐地震反应的影响

获取原文

摘要

To study the impact of floating roof on seismic response of vertical storage tank structure system subjected to seismic excitation, select 150000m~3 storage tanks as research object, and the finite element analysis model of storage tanks with and without floating roof were established respectively. The seismic response of these two types of structure in different site conditions and seismic intensity were calculated and the numerical solutions were compared. The results show that floating roof has little impact on base shear and base moment in different site conditions and seismic intensity. Floating roof can effectively reduce the sloshing wave height. The influence of floating roof on dynamic fluid pressure decreases with the increase of seismic intensity, which is less affected by ground conditions.
机译:为研究浮动屋顶对垂直储罐结构系统的地震响应的影响,选择150000m〜3个储罐作为研究对象,分别建立了储存箱的有限元分析模型,分别建立了储存箱的储罐。计算了不同部位条件和地震强度在不同部位条件下结构的地震反应,并比较了数值溶液。结果表明,浮屋屋顶对不同场地条件和地震强度的基础剪切和基地的影响几乎没有影响。浮顶可以有效地降低晃动波浪高度。浮动屋顶对动态流体压力的影响随着地震强度的增加而降低,其受地面条件的影响较小。