首页> 外文会议>International Conference on Instrumentation, Measurement, Computer, Communication and Control >Error Analysis of High-moisture Maize Moisture Measurement with PM-8188 Grain Moisture Tester
【24h】

Error Analysis of High-moisture Maize Moisture Measurement with PM-8188 Grain Moisture Tester

机译:PM-8188籽粒水分测试仪高湿玉米水分测量误差分析

获取原文

摘要

PM-8188 type capacitance grain moisture tester was used to detect the moisture of twenty-four maize hybrids in the period of harvest time and the period when the grain were naturally fully dehydrated, the results were compared with the results of grain weight change, and the changes of measurement errors in high moisture levels were discussed briefly. The results showed that the measurement error reached its minimum by the measured value of 26.2. The measured value was larger than the true value when below 26.2, but smaller when exceeded. And the measurement error increased with the deviation from 26.2.
机译:PM-8188型电容晶粒水分测试仪用于检测收获期间的二十四种玉米杂种的水分,并且当晶粒天然完全脱水时,将结果与粒重变化的结果进行比较,简要讨论了高水分水平测量误差的变化。结果表明,测量误差通过测量值26.2达到其最小值。测量值大于26.2以下时的真值,但在超过时更小。并且测量误差随26.2的偏差而增加。