The high temperature pneumatic ducts are the significant components of Air Management System (AMS). It acts as transfer pipe for air flow with high temperature and pressure. Its reliability is a key issue for the design of AMS. Due to the high temperature and high pressure of the air, the failure of pneumatic duct could even bring catastrophic hazard to aircraft. Considering operation condition of the duct, CAE models are developed in this paper, which is used to obtain the strain and stress distribution of the ducting system under different constraint. According to stress analysis, the damage or leakage spot would be determined. On this basis, leakage model is developed to analyze the internal pressure loss and external temperature distribution of the pneumatics ducts under accidental fault condition. These works would be helpful for the design and optimization of the high temperature pneumatic duct system.
机译:高温气动管道是空气管理系统(AMS)的重要组成部分。它充当带有高温和压力的空气流动的转移管。它的可靠性是AMS设计的关键问题。由于空气的高温和高压,气动管道的失效甚至可以为飞机带来灾难性的危险。考虑到管道的操作条件,在本文中开发了CAE模型,用于在不同约束下获得管道系统的应变和应力分布。根据压力分析,将确定损坏或泄漏点。在此基础上,开发出泄漏模型以分析意外故障条件下肺炎管道的内部压力损失和外部温度分布。这些作品对高温气动管道系统的设计和优化有所帮助。