Voltage unbalance or sag conditions generated by the power system faults can have a significant negative impact on the ASD's (Adjustable Speed Drives). A practical ride- through scheme based on supercapacitor/ battery as an energy storage device for ASD's is presented in this paper. Energy storage module is connected to support the DC-link voltage during power system faults. The performance of ASD's under normal and power system faults is first simulated in MATLab Simulink and then experimentally verified. The Data AcQuisition boards (DAQ) of National Instruments along with LabVIEW software have been used to record the observed waveforms.
机译:电源系统故障产生的电压不平衡或SAG条件可能对ASD(可调速度驱动器)产生显着的负面影响。本文介绍了基于超级电容器/电池的实际乘车方案作为ASD的能量存储装置。能量存储模块连接以在电源系统故障期间支持DC-Link电压。在Matlab Simulink中首先模拟ASD在正常和电力系统故障下的性能,然后通过实验验证。国家仪器的数据采集板(DAQ)以及LabVIEW软件的数据采集板已被用于录制观察到的波形。