首页> 外文会议>Corrosion Conference and Expo >Failure of an AISI 8630-Mod low alloy steel to C-Mn steel dissimilar metal weld, made using nickel alloy UNS N06625 welding consumables
【24h】

Failure of an AISI 8630-Mod low alloy steel to C-Mn steel dissimilar metal weld, made using nickel alloy UNS N06625 welding consumables

机译:AISI 8630-MOD低合金钢失效到C-MN钢异种金属焊接,采用镍合金UNS N06625焊接耗材制成

获取原文

摘要

Approximately one year after installation, it was discovered that a failure had occurred, in deep water, at a joint between an elbow from a water injection flowline and a forged connector to a subsea manifold. The line had separated at the welded joint between the AISI 8630-Mod (8630M) low alloy steel connector and the ASTM A694/A694M-03 - Grade F65 (F65) C-Mn steel elbow, made using nickel alloy UNS N06625 (Alloy 625) welding consumables. Although this type of joint is commonly employed subsea, there have been a few failures and this combination of materials is no longer preferred for this type of service. Both halves of the fractured joint were retrieved from the seabed for failure investigation. A detailed investigation was undertaken, including extensive visual inspection, metallography and fractography, using scanning electron microscopy, to characterise the fracture event, fracture morphologies and corresponding microstructures. It was also attempted to estimate the loads which might have been responsible for fracturing the joint. In addition, supporting tests and examinations were carried out on the materials, to assess the assembly against the original construction specifications. The paper presents the observations made and discusses the failure mechanism and its relationship with the environmental conditions encountered.
机译:在安装后大约一年,发现在深水中发生了故障,从水喷射流线线和锻造连接器到海底歧管的锻造连接器之间发生了失败。该线在AISI 8630-MOD(8630M)低合金钢连接器和ASTM A694 / A694M-03级F65(F65)C-MN钢肘之间的焊接接头处分开,采用镍合金UNS N06625(合金625 )焊接耗材。虽然这种类型的关节是普遍采用的海底,但已经有一些故障,这种材料的组合不再优选这种类型的服务。从海底检索破裂关节的两半用于故障调查。进行了详细的研究,包括使用扫描电子显微镜的广泛的视觉检验,金相和断裂,以表征骨折事件,断裂形态和相应的微观结构。还试图估计可能负责压裂关节的负荷。此外,在材料上进行支持测试和检查,以评估组件对原始施工规范。本文提出了对失败机制的观察及其与遇到的环境条件的关系。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号