Considering their location in a high radiation environment and the alignment tolerances requested, the low beta quadrupoles of LHC will be positioned remotely (controlling 5 degrees of freedom), with a displacement resolution of few microns in horizontal and vertical. Stepping motor gearbox assemblies are plugged into the jacks which support the cryomagnets in order to move them to the desired position regarding the quality of the beam collisions in the detectors. This displacement will be monitored in real time by the sensors located on the magnets. This paper describes the positioning strategy implemented as well as the software tools used to manage it.
机译:考虑到它们在高辐射环境中的位置和所请求的对准公差,LHC的低β四轮节将远程定位(控制5度的自由度),在水平和垂直的较小微米中的位移分辨率。 步进电机齿轮箱组件插入支撑低温磁头的插孔中,以便将它们移动到关于检测器中的光束碰撞质量的所需位置。 该位移将由位于磁铁上的传感器实时监控。 本文介绍了实现的定位策略以及用于管理它的软件工具。