首页> 外文会议>Biennial European Particle Accelerator Conference >SETUP AND COMMISSIONING OF THE DIAGNOSTICS BEAMLINE FOR THE SRF PHOTOINJECTOR PROJECT AT ROSSENDORF
【24h】

SETUP AND COMMISSIONING OF THE DIAGNOSTICS BEAMLINE FOR THE SRF PHOTOINJECTOR PROJECT AT ROSSENDORF

机译:在Rossendorf的SRF PhotoInjector项目的诊断束线设置和调试

获取原文

摘要

A superconducting radio frequency photo electron injector (SRF injector) has been developed by a collaboration of BESSY, DESY, FZD and MBI and is in operation since late 2007. After the initial commissioning in late 2007 with a Copper photocathode a Caesium-Telluride cathode was installed early 2008 to allow for high charge production. The longitudinal and transverse electron beam parameters are measured in a compact diagnostics beamline. This paper describes results from beam commissioning of the main diagnostic tools. Special emphasis is given on the bunch length measurement system for the 15 ps FWHM electron bunches. The system is based on the conversion of the electron pulses into radiation pulses by Cherenkov radiation. These radiation pulses are transported in a novel fullyreflective, relay imaging optical beamline to a streak camera, where the temporal properties of the pulses are measured.
机译:通过Bessy,Desy,FZD和MBI的协作开发了超导射频照片电子喷射器(SRF注射器),并且自2007年末开始运作。2007年后的初步调试用铜光电阴极铯 - 碲化铯阴极之后 安装于2008年初,以允许高电荷生产。 纵向和横向电子束参数在紧凑的诊断束线中测量。 本文介绍了主要诊断工具的光束调试结果。 对15 PS FWHM电子束的束长测量系统给出了特殊的重点。 该系统基于Cherenkov辐射将电子脉冲转化为辐射脉冲。 这些辐射脉冲以新颖的全重选择性的继电器成像光学束线输送到条纹相机,其中测量脉冲的时间特性。