This paper presents the operation of the multilevel inverter based shunt active filter. This shunt active filter is operated by an innovative extraction technique which is the least square technique; this technique generates the reference signal to operate the shunt active filter. The multilevel inverter is selected as a proposed topology for the active filter because it has several merits over the traditional 2-level inverter. The selected topology is operated by the improved time-based hysteresis switching strategy. The propounded ideas are proved by the simulation results using SIMULINK/MATLAB.
机译:本文介绍了基于多级逆变器的分流器有源滤波器的操作。这种分流器有源过滤器通过创新的提取技术操作,该技术是最小的技术;该技术产生参考信号以操作分流器有源滤波器。将多级逆变器选择为有源滤波器的提出拓扑,因为它在传统的2级逆变器上有几个优点。所选择的拓扑由改进的基于时间的滞后切换策略操作。使用Simulink / Matlab的仿真结果证明了接种的想法。