首页> 外文会议>International conference on environmental technology and knowledge transfer >Air Flotation Experiment on the Rolling Steel Cooling Water of Angang Steel Company Limited
【24h】

Air Flotation Experiment on the Rolling Steel Cooling Water of Angang Steel Company Limited

机译:鞍钢钢铁公司轧钢冷却水的空气浮选试验

获取原文

摘要

Many series of experiments were carried on for settling the problems that floc went down and effluent quality wasn't stable and could not meet the effluent-quality standard. Through changing the category and proportion of the flocculating agents, the optimum experiment condition was studied and summarized. The optimum condition of flocculating agents and concentration per 500 mL waste water was: PAC:PAF 4:1, 10%, 1.25 mL; PAM 0.1%, 1 mL; sodiumoleate 4:1, 1.25% 0.5 mL; the operation stirring speed was 1,000-1,200 r/min, and the mixing time was 5-8 s.
机译:许多系列的实验进行了解决,用于解决絮状物的问题,流出质量不稳定,无法满足污水质量标准。通过改变絮凝剂的类别和比例,研究和总结了最佳实验条件。絮凝剂的最佳条件和每500ml废水浓度为:PAC:PAF 4:1,10%,1.25ml; PAM 0.1%,1毫升;钠4:1,1.25%0.5 ml;操作搅拌速度为1,000-1,200 r / min,混合时间为5-8秒。