首页> 外文会议>International conference on environmental technology and knowledge transfer >Study on Impact Factors of Removing Capacity of Organism in Bio-contact Oxidation
【24h】

Study on Impact Factors of Removing Capacity of Organism in Bio-contact Oxidation

机译:生物接触氧化能力消除能力的影响因素研究

获取原文

摘要

Employing bio-contact oxidation to treat sewage, the impact of HRT (hydraulic retention time), hydraulic load and volume load on removing capacity of organism in the system were observe in this study. The results indicated that the removing rate of COD (chemical oxygen demand) in bio-contact oxidation was able to satisfy substandard 1 of urban drainage standard 2 in the "integrated wastewater discharge standard" (GB8978-1996) under this condition: the temperature 17-21 °C, DO (dissolved oxygen) 2.5-3.5 mg/L, pH 6.57.5. Meantime, when HRT stayed at about 9h, hydraulic load kept at 0.66-0.91 m3/(m2·d), and the volume load was 810 kg/(m3.d), the treating effect of urban wastewater by bio-contact oxidation was better.
机译:采用生物接触氧化治疗污水,在本研究中观察到系统中HRT(液压保留时间),液压载荷和体积负荷去除生物体中的容量的影响。结果表明,在这种条件下,生物接触氧化中的鳕鱼(化学需氧量)中的鳕鱼(化学需氧量)可以满足城市排水标准2(GB8978-1996)中的不合标准1:温度17 -21°C,做(溶解氧)2.5-3.5mg / L,pH6.57.5。同时,当HRT保持在大约9h时,保持在0.66-0.91m3 /(m2·d)的液压载荷,并且体积负荷为810千克/(m3.d),通过生物接触氧化来调整城市废水的治疗效果更好的。