首页> 外文会议>International symposium on innovation sustainability of structures in civil engineering >SEISMIC BEHAVIOR OF MOMENT CONNECTIONS FOR CONCRETE- FILLED SQUARE STEEL TUBE EDGE COLUMN
【24h】

SEISMIC BEHAVIOR OF MOMENT CONNECTIONS FOR CONCRETE- FILLED SQUARE STEEL TUBE EDGE COLUMN

机译:混凝土钢管边缘柱的时刻连接的地震行为

获取原文

摘要

A total of three interior diaphragm connections which have only three of the edges welded to the tubes for concrete filled square steel tube with different axial load ratios had been tested under low-cyclic reversed loading at the end of column to investigate the failure modes, ductility, energy dissipation behavior. The experimental results demonstrated that the vertical force on the side of the interior diaphragm welded to the column flange was about one third of that on the other side. When the displacement of the top of column was approximate 70mm, the local buckling of the beam flanges occurred where the interior diaphragm was welded to the column flanges. The results indicated that all specimens had very good ductility and energy dissipation capacity. The story angle drift ductility ratios are μ=3.40~3.45, the elastic and elasto-plastic story angular drift are Φy=0.0075~0.0083rad and Φu=0.0279~0.0286rad respectively, and the equivalent viscous damping coefficients are he=0.426~0.462, which met the requirements of the current code for seismic design of buildings. The interior diaphragm connection, which has only three of the edges welded to the tubes, can be used for edge column connections.
机译:在柱末端的低环状反转载荷下,在柱状的低循环反转载荷下,总共具有焊接到混凝土填充方形钢管管的三个内部边缘的三个内部隔膜连接,以研究失效模式,延展性,能量耗散行为。实验结果表明,焊接到柱凸缘的内部隔膜侧的垂直力约为另一侧的三分之一。当塔顶部的位移近似为70mm时,梁法兰的局部屈曲,其中内部隔膜焊接到柱凸缘。结果表明,所有标本都具有非常好的延展性和能量耗散能力。故事角漂移延展比例是μ= 3.40〜3.45,弹性和弹性塑料故事角漂移是φY= 0.0075〜0.0083rad和φu= 0.0279〜0.0286Rad,等效的粘性阻尼系数是他= 0.426〜0.462 ,符合当前建筑物地震设计规范的要求。内部隔膜连接只有三个焊接到管的边缘,可用于边缘柱连接。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号