Function of an electrostatic precipitator using bipolar corona discharges

机译:使用双极电晕放电静电除尘器的功能

获取原文

摘要

The discharge spikes in the ionizer of the ESP (electrostatic precipitator) with bipolar corona-discharge are arranged not only in the energized-plates but also in the grounded-plates. The discharge from the spikes in the grounded-plates generates ions of opposite polarity to those from the energized-plates. A two-stage-type ESP with bipolar-corona discharge is composed of the ionizer and a collector to which DC high voltage is applied. In the previous test, this bipolar collection method, using positive and negative discharges simultaneously, proved that the particles were enough collected. In this report, discharge-current-density and attached-particles on the ionizer-plates have been discussed in order to clarify the charging-mechanism in the bipolar discharge.
机译:具有双极电晕 - 放电的ESP(静电除尘器)的离子发生器中的放电钉不仅在通电板中布置,而且在接地板中布置。 从接地板中的尖峰的排出产生与来自通电板的相反极性的离子。 具有双极电晕放电的两级型ESP由离子发生器和施加DC高压的集电器组成。 在先前的测试中,这种双极收集方法同时使用正和负放电,证明了颗粒足够收集。 在本报告中,已经讨论了放电 - 电流密度和连接颗粒,以澄清双极放电中的充电机制。