A 38 MMSCF/D Cooper Bessemer Model LM-9 reciprocating compressor in hydrogen service at the Praxair Westlake LA facility has experienced notable particulate contamination within the feed gas. The particulates were believed to be caused by upstream piping corrosion; however, to definitely state the cause, the properties of the fluid existing in the five-stage compressor needed to be more fully understood. An OLI electrochemical simulation software was used for dew point prediction, determination of the condensed phase ionic equilibria, and corrosion rate prediction. These tasks were beyond capabilities of the site-licensed UniSim software, as presently configured. Specifically, the model was used to identify the dew point conditions (temperature, pressure) and properties of the condensed water (pH, corrosivity, dissolved O_2, and chlorine speciation). Model results were compared with site inspection findings. Subsequently, recommended limits for chlorine and oxygen in the feed gas were established to improve long term compressor reliability.
机译:Praxair Westlake La设施在氢气服务中的38 MMSCF / D Cooper Bessemer型号LM-9往复式压缩机在进料气体中经历了显着的颗粒状污染。据信颗粒是由上游管道腐蚀引起的;然而,为了肯定地说明原因,在五阶段压缩机中存在的流体的性质需要更全面地理解。 OLI电化学仿真软件用于露点预测,测定冷凝相离子均衡和腐蚀速率预测。这些任务超出了本网站许可的Unisim软件的功能,如目前已配置。具体地,该模型用于鉴定露点条件(温度,压力)和冷凝水(pH,腐蚀性,溶解O_2和氯气格)的性质。将模型结果与位点检查结果进行比较。随后,建立了进料气体中氯和氧的推荐限制,以提高长期压缩机可靠性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号