首页> 外文会议>SME annual meeting exhibit >EFFECT OF LONGWALL FACE ADVANCE ON SPONTANEOUS HEATING IN LONGWALL GOB AREA
【24h】

EFFECT OF LONGWALL FACE ADVANCE ON SPONTANEOUS HEATING IN LONGWALL GOB AREA

机译:长墙面对长墙戈布地区自发加热的影响

获取原文

摘要

To reduce fire hazards from spontaneous combustion of coal in longwall gob areas, a series of computational fluid dynamics (CFD) simulations were conducted by National Institute for Occupational Safety and Health (NIOSH) to model the spontaneous heating of coal in longwall gob areas. The previous modeling results demonstrate that spontaneous heating of coal usually occurred behind the longwall shields and along the face with a bleeder ventilation system. Assuming a stationary longwall face, the spontaneous heating could turn to a spontaneous fire in several days for the most reactive coal under favorable conditions. When the longwall face advances, the spontaneous heating process will be significantly affected. In this study, the effect of longwall face advance on the spontaneous heating in the gob area is investigated using the CFD model developed in previous studies. One longwall panel with a bleeder ventilation system is simulated. The width of the panel is 300 m, while the length of the panel is changed between 1,000 to 2,000 m. The same permeability and porosity profiles are used for gobs with different lengths. The spontaneous heating first develops in the gob when the longwall face is stationary. Then, the face advances at a certain rate. The face advance is simulated as a series of discrete movements, and the effect of the face advance on the maximum temperature developed during the face stoppage is examined. Disclaimer: The findings and conclusions in this report are those of the authors and do not necessarily represent the views of the National Institute for Occupational Safety and Health.
机译:为了减少长墙戈布地区煤炭自燃灾害的火灾,由国家职业安全和健康研究所(Niosh)进行了一系列的计算流体动力学(CFD)模拟,以模拟长墙GOB地区的煤炭自发加热。以前的建模结果表明,煤的自发加热通常发生在长墙屏蔽后面和沿着玻璃通风系统的面部。假设一个固定的长壁面,自发加热可以在有利条件下为最活力的煤变为自发的火灾。当长壁面前的进步时,自发加热过程将受到显着影响。在这项研究中,使用先前研究中开发的CFD模型研究了LongWALL面对对GOB区域中自发加热的影响。模拟一个带有泄放通风系统的长墙板。面板的宽度为300米,而面板的长度在1,000至2,000米之间变化。相同的渗透率和孔隙率曲线用于具有不同长度的甘油。当长墙面静止时,自发加热首先在凝球中发育。然后,面对一定的速度前进。面部前进被模拟作为一系列离散运动,并且检查了面部前进对在面部停止期间产生的最大温度的效果。免责声明:本报告中的调查结果和结论是作者的调查结果,并不一定代表国家职业安全和健康研究所的意见。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号