According to the application of radiant floor heating, system design, and laying status, this paper advances a design idea of using natural cooling source such as ground water or evaporation cooling water for 'free cooling'. Based on the above, a mathematic model of low-temperature radiant floor heating/cooling is constructed. This paper studies the matching of radiant floor's cooling capacity and building load, which is in the radiant floor cooling situation that meets thermal comfort of occupants, and in the precondition of fixed parameters such as supply and return water temperature, difference in temperature, flux, existing pipe distance, floor board material and others. In the next place, the change range of indoor air dew point temperature is analyzed in different indoor and outdoor environment operation situation. Combined with the model mentioned above, in the floor non-dewfall condition, the application scopes and optimal values of correlative design parameters are suggested. Finally, this paper considers the synthetically conditions of human thermal comfort and non-dewfall of floor, and then puts forward the feasibility suggestion and applicability project of summer cooling in existing radiant floor system.
机译:根据地板辐射采暖,系统设计和铺设状态的应用,本文前进使用自然冷却源,例如地下水或蒸发冷却水“自由冷却”的设计理念。基于上述,低温辐射地板加热的数学模型/冷却构造。本文研究地板辐射的匹配真实冷却能力和建筑物负荷,这是在满足乘客的热舒适的地板辐射冷却的情况下,以及在固定的参数,例如电源和回水温度,温度差,磁通的前提下,现有管的距离,地板材料等。在未来的地方,室内空气的露点温度的变化范围在不同的室内和室外环境的操作情况进行了分析。与模型结合上面提到的,在底板非结露状态,应用范围和相关的设计参数最佳值是建议。最后,本文认为的人体热舒适性和地面的非结露的综合条件,并提出可行性建议,夏季现有的地板辐射系统冷却的应用项目。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号