This paper presents the power energy effect under unbalance condition and discusses the relation between power loss and unbalance degree. Then a new topology structure of SVC based on the principle of unbalance compensation is proposed to solve the unbalance problem in power system and the energy efficiency is analyzed by an actual experiment with the compensation of the new SVC. The experimental results demonstrate that the power energy loss can be saved by 20% or so after compensation. Therefore, it can bring more benefit for both society and economic.
机译:本文介绍了不平衡条件下的功率效应,并讨论了功率损耗和不平衡程度之间的关系。然后,提出了一种基于不平衡补偿原理的SVC的新拓扑结构,以解决电力系统中的不平衡问题,并通过实际实验分析了新SVC的实际实验的能效。实验结果表明,在补偿后,功率损失可以节省20%左右。因此,它可以为社会和经济带来更多的利益。